STX IP20 RJ45 plug AWG24-27 Cat.6A black
STX IP20 RJ45 plug AWG24-27 Cat.6A black
Technical attributes
Article name | CU-CN STXRJ45plg 24-27 C6A cb bk |
---|---|
Remarks | AWG24-27, with cable boot (black) |
Downloads
Description of the Series/Product Category
Notice: The following information refer to the series/product category as a whole. Please see the specific datasheet for specific technical information of a particular product.
For the assembly of RJ45 patch cords Telegärtner offers RJ45 plugs using no special tools as well as for crimp termination. The RJ45 connectors acc. to IEC 60603-7 are available in several designs. The 8-way Cat.6A MFP8 connector for stranded and solid wire cables can easily be assembled onsite without any special tools. The maximum cable diameter is 9.0 mm. The connector features the T568 A/B or PROFINET pin assignment and a 360º shielding connection. An unshielded version of the 8-way Cat.6A UFP8 connector for stranded AWG27/7-22/7 or solid wire cables AWG24/1-22/1 can easily be assembled onsite without any special tools. The maximum cable diameter is 8.5 mm. The 8-way Cat.6A connector MP8 FS for stranded and solid wire cables completes the product line. Assembled with a crimp tool it offers shielding connection and a wire presorting for easy handling, too. The strain relief pressure is thereby absorbed by the cable jacket. This avoids deformation of wires. 1-part and 2-part cable boots in different colours are available additionally. Suitable crimp tools, one for less frequent usage (> 1.000 operations), the other for professional application (> 10.000 operations) round-off the product range. All connectors are capable for use in multiport-applications such as patch panels, switches, etc.
Performance characteristics
pre-assembled protection cap
robust zinc diecast housing
360° shielding
full metal shielding between pairs of wires
three strain relief settings (cable diameters 5.0 mm to 9.0 mm)
can be assembled in 60 seconds without any special tools
optimised for the field, including demanding applications
secure transmission even with outside interference
four-chamber wire manager (available with colour code T568A or T568B and PROFINET)
suitable for cabling in office buildings, data centers, industrial facilities and home networks
supreme reliability
ideal for network repairs, special lengths and extensions
piercing contacts suitable for solid and stranded conductors
Mechanical attributes
Insertion force | ≤ 30 N |
---|---|
Durability (Matings) | ≥ 750 |
Reusable contacts | ≤10 cycles |
Cu-Conductor diameter: solid | 0.51 - 0.64 mm (AWG24/1-22/1) |
Cu-Conductor diameter: stranded | 0.46 - 0.61 mm AWG 27/7 - AWG 24/7 |
Mating Requirements Cu-Conductor diameter: stranded | 0.61 - 0.78 mm (AWG24-22/19) |
Core Diameter | 0,8 - 1,1 mm |
Material: contacts | phosphor bronze |
Material: contact finish | min. 0,8 µm Au on 2,54 µm Ni |
Material: connector housing | PC UL94 V0 |
Material: PCB | FR4 UL 94 V0 |
Material: piercing contacts | phosphor bronze tinned |
Material: shield contact | brass, nickel-plated |
Material: wire pair presorting | PC UL94 V0 white |
Material: uplock hook | PBT UL94 V0 |
Material: shielding housing | zinc diecast, nickel-plated |
Material: cable clamp | PBT UL94 V0 |
Material: protection cap | PBT UL94 V0 |
Mating Requirements Cu-Conductor diameter: solid | 0.36 - 0.51 mm AWG 27/1 - AWG 24/1 |
Mating Requirements Cu-Conductor diameter: stranded | 0.46 - 0.61 mm AWG 27/7 - AWG 24/7 |
Cable diameter | 5.0 - 7.3 mm |
Material: contacts | Phosphorbronze |
Material: shield | brass |
Material: shield finish | 2 µm Ni |
Material: cable boot | PA UL94 V0 black |
Thermal and climatic attributes
Temperature range [°C] | -40/ 85 |
---|---|
UL | E244889 |
Elecrical attributes
PoE+ acc to IEEE 802.3at | fulfilled |
---|
Transmission properties
10 Gigabit Ethernet acc. to IEEE 802.3an | fulfilled |
---|---|
Category 6^A (Component) | ISO/IEC 11801, EN 50173-1 |
Class E^A (Channel) | ISO/IEC 11801, EN 50173-1 |
Norms
Connectors | IEC 60603-7-51 |
---|---|
Generic cabling systems | ISO/IEC 11801; EN 50173-1:2007; ISO/IEC 24702; IEC 61918 |