homeapartmentpencilmagic-wanddroplighterpoopsunmooncloudcloud-uploadcloud-downloadcloud-synccloud-checkdatabaselockcogtrashdiceheartstarstar-halfstar-emptyflagenvelopepaperclipinboxeyeprinterfile-emptyfile-addenterexitgraduation-hatlicensemusic-notefilm-playcamera-videocamerapicturebookbookmarkuserusersshirtstorecarttagphone-handsetphonepushpinmap-markermaplocationcalendar-fullkeyboardspell-checkscreensmartphonetabletlaptoplaptop-phonepower-switchbubbleheart-pulseconstructionpie-chartchart-barsgiftdiamondlineariconsdinnercoffee-cupleafpawrocketbriefcasebuscartrainbicyclewheelchairselectearthsmilesadneutralmustachealarmbullhornvolume-highvolume-mediumvolume-lowvolumemichourglassundoredosynchistoryclockdownloaduploadenter-downexit-upbugcodelinkunlinkthumbs-upthumbs-downmagnifiercrossmenulistchevron-upchevron-downchevron-leftchevron-rightarrow-uparrow-downarrow-leftarrow-rightmovewarningquestion-circlemenu-circlecheckmark-circlecross-circleplus-circlecircle-minusarrow-up-circlearrow-down-circlearrow-left-circlearrow-right-circlechevron-up-circlechevron-down-circlechevron-left-circlechevron-right-circlecropframe-expandframe-contractlayersfunneltext-formattext-format-removetext-sizebolditalicunderlinestrikethroughhighlighttext-align-lefttext-align-centertext-align-righttext-align-justifyline-spacingindent-increaseindent-decreasepilcrowdirection-ltrdirection-rtlpage-breaksort-alpha-ascsort-amount-aschandpointer-uppointer-rightpointer-downpointer-left

Tipos de conectores de fibra óptica

Good fiber optic connectors have low attenuation and high return loss. But what exactly is “good“? IEC 61753-1 specifies performance grades for fiber optic connectors.

 

IEC 61753-1 and the European issue EN IEC 61753-1 specify performance grades for attenuation and return loss. For attenuation grades letters from A to D are used and for return loss grades numbers ranging from 1 to 4. Not all grades are finalized yet, some are still for further studies.

 

Attenuation

Connectors for singlemode fibers
Attenuation at 1310 nm, 1550 nm and 1625 nm

Grade A

for further studies

Grade B

max. 0.12 dB average value max. 0.25 dB limit for min. 97% of all connectio

Grade C

> max. 0.25 dB average value

max. 0.5 dB limit for min. 97% of all connections

Grade D

max. 0.5 dB average value max. 1.0 dB limit for min. 97% of all connections

Return lossConnectors for singlemode fibers Return loss at 1310 nm, 1550 nm and 1625 nm
Grade 1min. 60 dB plugged-in and min. 55 dB unplugged
Grade 2min. 45 dB
Grade 3min. 35 dB
Grade 4min. 26 dB

 

AttenuationConnectors for multimode fibers Attenuation at 850 nm
Grade Amfor further studies
Grade Bmmax. 0.3 dB average value max. 0.6 dB limit for min. 97% of all connection
Grade Cmmax. 0.5 dB average value max. 1.0 dB limit for min. 97% of all connections
Grade Dmfor further studies

 

Return lossConnectors for multimode fibers
Grade 1mfor further studies
Grade 2mmin. 20 dB

Caption: Performance grades of randomly mated fiber optic connectors as specified by IEC 61753-1:2018. Testing singlemode connectors at 1625 nm are optional for enterprise applications but mandatory for carrier applications. Performance grades of field-installable singlemode connectors are still under discussion.

Clases de calidad según DIN EN IEC 61753-1:2019-10 para conectores de fibra óptica ensamblados al azar. Las pruebas de conectores monomodo a 1625 nm son opcionales para aplicaciones empresariales, pero obligatorias para aplicaciones de portadoras; sin embargo, la norma no define estas aplicaciones. Las clases de atenuación para conectores monomodo montables en campo están en proceso de consulta según DIN EN IEC 61753-1:2019-10.

Contact

Dirk Träger

Dirk Träger


Downloads

[Translate to Spanisch:] FactSheet: FO Connector Grades 355 KB

Related News

PoE en diferentes sabores

Alimentación a través de Ethernet

PoE, PoE+, PoE++, 4PPoE... siga leyendo para saber qué versiones PoE reconoce la norma.

Seguir leyendo

Código del cable de fibra óptica

Cables FO

A/I-DQ(ZN)BH 12G50/125, I-VHH 2E9/125: estos y otros códigos similares están impresos en la cubierta de los cables de fibra óptica. Siga leyendo para…

Seguir leyendo

Diferencia entre contactos IDC e IPC

Contactos IDC

Los contactos IDC e IPC terminan los hilos de un cable en una toma, módulo o clavija. Sigue leyendo para conocer la diferencia entre estos dos tipos…

Seguir leyendo

Enlaces de extremo a extremo - Enlace de extremo a extremo (enlace E2E)

Módulos RJ45

Allí donde las tomas de telecomunicaciones y los cables de conexión no son necesarios, los dispositivos electrónicos se conectan al cable horizontal.…

Seguir leyendo